FREE-STANDING TUBE WALL STRUCTURE FOR
GEARGRID TURNOUT GEAR LOCKERS
PART 1 GENERAL
1.1 SECTION INCLUDES
A. Design, fabrication and installation of free-standing tube wall structure as specified herein.
NOTE: GEARGRID FREE-STANDING TUBE WALL STRUCTURES ARE DESIGNED FOR USE WITH GEARGRID WALL MOUNT LOCKERS ONLY. GEARGRID ASSUMES NO LIABILITY OR RESPONSIBILITY AND GIVES NO WARRANTY FOR USING FREE-STANDING TUBE WALL STURCTURE WITH ANY OTHER LOCKER TYPES OR MANUFACTURER’S PRODUCT.
1.2 RELATED SECTIONS
A. Section 10: Metal Wire Grid Lockers
1.3 SUBMITTALS
A. Product Data: Submit manufacturer’s product data and installation instructions.
B. Shop Drawings: Submit manufacturer’s shop drawings for each individual free-stranding unit of lockers.
C. Samples: Submit manufacturer’s standard color samples.
D. Owner’s Manual: Provide maintenance manual at closeout.
E. Warranty: Submit manufacturer’s standard warranty.
1.4 QUALITY ASSURANCE
A. Manufacturer shall have a minimum of five years experience in the direct manufacture of lockers and wall mounting systems.
B. Free-Standing Tube Wall Structure must be manufactured in United States of America.
C. Installer shall have 5 years of experience in locker assembly.
1.5 DELIVERY, STORAGE AND HANDLING
A: Delivery: Deliver materials to site in manufacturer’s original, unopened containers with labels identifying product and manufacturer’s name.
B: Storage: Store materials in a clean dry area.
C: Handling: Protect materials and finish during installation and handling to prevent damage.
PART 2 PRODUCTS
2.1 MANUFACTURER
A. GearGrid LLC 670 SW 15th Street, Forest Lake, MN 55025. Toll-free 888-643-6694. Phone 651-464-4468. Fax 651-464-4780. Web site www.geargrid.com. Email sales@geargrid.com.
B. NO SUBSTITUTIONS PERMITTED
2.2 FREE-STANDING TUBE WALL STRUCTURE
A. Model: (FSTWS) Free-Standing Tube Wall Structure Units
B. Free-Standing Tube Wall Structures are engineered specifically for each installation and are designed to ship in a knocked-down configuration for efficient shipping. Wall structure components are bolted together with hardware as supplied or identified.
C. Construction: Units shall be welded at all applicable joints. Forming of metal shall be completed by standard cold-forming operations. Use of fasteners will only be required to allow for knock-down shipping, securing units to mounting surface and on applicable accessories.
1. Vertical Posts: 4” x 4”, .250” wall thickness ASTM A513 steel tube
2. Floor Mounting Plates: ½” steel plate welded to Vertical Posts. 3/8” mounting holes as needed.
Mounting plate hole configurations subject to locker layout
3. Horizontal Frames: 4” x 4”, .1875” wall thickness ASTM A513 steel tube. Frames mechanically fastened to Vertical Posts with supplied or identified hardware.
a. Note: If PowerBars (Electric Raceway) are used, top Horizontal Frame will be 6” high x 4” wide, .1875” wall thickness steel tube
2.4 FINISH
A. General: All system components excluding assembly and mounting hardware and stainless steel components are to receive the standard finish.
B. Standard Finish: Components to be cleaned using a phosphatized bath, clear water rinse and electro-statically coated with a durable TGIC powder coating.
C. Color: _______________
Part 3 EXECUTION
3.1 EXAMINATION
A. Examine areas to receive Free-Standing Wall Structures. Notify architect if areas are not acceptable. Do not begin installation until unacceptable conditions have been corrected.
3.2 INSTALLATION
A. Assemble free-standing lockers in accordance with manufacturer’s instructions.
B. Use manufacturer’s hardware for assembly.
NOTE: SEE SAMPLE DRAWINGS NEXT PAGE
FREE-STANDING TUBE WALL STRUCTURE – EXAMPLE DRAWINGS
FOR REFERENC ONLY